What a power cut can do to your business IT

By Benjamin ReichertNetworks, hardware, support · IT specialist for system integration (Fachinformatiker, IHK)Last updated:
The lights flicker, the monitors go black, three seconds later everything is back. You shrug and carry on working.
That very moment is the dangerous one. A workstation usually gets through it with an unwanted restart. A server or a NAS that happens to be writing at that moment may, at worst, not get through it.
The precaution against this is manageable: a UPS (uninterruptible power supply) on the right devices, an automatic shutdown that has been set up, and a known order for restarting. The rest of the article goes through these three points.
How often the power actually goes out
The Bundesnetzagentur reports that, in 2024, electricity customers in Germany lost power for an average of 11.7 minutes. The German grid is among the most reliable in Europe. The statistics count only outages lasting more than three minutes, so a two-second interruption is missing from the figures. A laptop with a battery can keep running. For a NAS, a brief interruption cuts power just as abruptly as an hour-long outage.
Then there is the situation here. If you are in the centre of Plauen, you are on different lines from a business out in the villages and outlying areas, where the medium-voltage line often runs through the forest as an overhead line. There a summer thunderstorm is enough, and the power is briefly gone. Thunderstorms also bring surges: insurers counted around 180,000 lightning and surge claims for 2025 — the figure comes from private insurance, but the order of magnitude applies to every socket.
What an abrupt loss of power does to devices
A computer does not write data to the disk at once but first collects it in a cache. If the power is cut, that cache is gone. What remains are half-written files, in the worse case a damaged file system, and in a RAID array the disks can end up in different states. A common misconception: RAID protects against the failure of a single disk, not against power loss. And it is no substitute for a backup — what a backup worth the name looks like is covered in the guide on the 3-2-1 rule.
The second blow often comes only when the power returns: as a voltage spike. Power supply units are hit most often. The typical picture afterwards: the NAS no longer starts, is invisible on the network or suddenly reports under a different address.
Two devices are regularly forgotten. The till: in a cut, the sale in progress is lost, locally stored till data is at risk, and a failure of the TSE must be documented. And the telephone: landlines now run over the internet. Without a powered router the line is dead — unlike the old analogue handset, which was fed through the telephone line.
What belongs on the UPS — and what does not
Connect the equipment that holds data or keeps you reachable to the battery-backed outlets: the server, the NAS, the till and the network chain of modem, router and switch. The router draws very little power and decides whether your phone and card payments get through the outage.
If the power fails across the whole village, though, the provider’s equipment is often affected too. Then the internet stays down even though your router is running, and the telephone is silent despite the UPS. In that case the mobile phone is the fallback, and the most important numbers should therefore not be only on the landline phone.
The laser printer does not belong on the UPS. When heating up, its fuser unit briefly draws very high currents, which can overload a small UPS or make it switch off (the manufacturers themselves expressly advise against it). Monitors and workstations are a matter of judgement; they are not needed for shutting the central devices down cleanly.
Which type, which size
There are three classes. Offline units simply pass the mains power through in normal operation and switch to the battery only on failure, with a gap of up to ten milliseconds. That is enough for a single PC or the router; from about €50 it is the cheapest class.
One step up are line-interactive units: they also continuously correct overvoltage and undervoltage and switch over faster. This is the usual choice for small servers, NAS and phone systems; a 2,000 VA unit costs from about €180.
Which size your devices need is worked out by the UPS calculator: select server, NAS, router and till, enter the bridging time you want, and it gives the power class and type.
The top class is online units (double conversion): they permanently regenerate the output voltage themselves. No switching gap, the best protection against mains disturbances, but the most expensive class with the poorest efficiency. You need this if you really cannot tolerate a single interruption.
To size a UPS, add up the wattage of the connected devices and allow some headroom. More important than the last watt-hour is a realistic idea of the bridging time. A small UPS typically lasts five to thirty minutes depending on load, and often only a few minutes at real full load. That is not a window for carrying on working but the time for an orderly shutdown. In our experience, a NAS can easily need ten minutes for that, hence the headroom. If you want to keep working during an outage, you are talking about a standby generator, and that is a different project. Nor is an ordinary UPS lightning protection: a surge from a nearby strike calls for a multi-stage protection concept starting at the meter cabinet, and that is a job for the electrician.
The cable that makes the difference
A UPS without a data connection only postpones the hard cut. After twenty minutes the battery is empty, and the NAS dies the same death as without a UPS, just later and with nobody in the building.
Connect the UPS to the NAS or server with the supplied USB cable and configure automatic shutdown. For example, a Synology NAS running on battery power can shut down after a delay you set or enter a safe mode that unmounts its drives. It can also relay the outage signal to other devices on the network.
And then: try it once. After closing time, pull the UPS’s mains plug and watch whether the chain really runs through. A shutdown that has been configured but never tested is a good intention, not a precaution.
When the power comes back
Restart devices in order. Let the modem and router start up fully first, then the firewall and switches. Next come the NAS and server, and the workstations last. Give each device a few minutes: routers like to report that they are ready early, before name resolution and address assignment behind them are working. That is why, after an outage, people often report that “the internet is broken” when nothing is broken.
Then two checks that we recommend to every business. First, check whether the data backup has run again after the outage instead of assuming it — how to prove that is covered in the guide on the restore test. Second, with a till, note the outage period with date and time; that is part of the documentation of the TSE failure.
In short
Your IT gets through a power cut if three things have happened beforehand: the right devices are on a suitably chosen UPS, the automatic shutdown is set up and tested, and the restart has a known order. Measured against a data recovery or two days of downtime, that is a small investment.
We set this up across the Vogtland, from a single NAS to a server rack with a phone system. Before the appointment, we explain what equipment and work you will need. Our servers & virtualisation page explains how we plan and support servers.