Wi-Fi Planner: How Many Access Points Do You Need?
In a brick house, one access point or mesh unit covers about 55 to 105 m² per floor, in an office with lightweight partitions 100 to 180 m² and in an open hall 400 to 700 m². Reinforced concrete and metal quickly cut that to half and below. From area, construction and devices, the planner works out your range and tells you when only an on-site measurement gives the exact number.
- free
- no sign-up
- runs in your browser
01 / PLANNER
Your building, your range
Planner · guide values, not a measurement
The planner calculates with guide values from manufacturers’ documentation and from our own jobs. It cannot see walls, furniture or your neighbours’ Wi-Fi. That is why it gives a range and says when only an on-site measurement gives the exact number.
02 / CALCULATION
How do you calculate the number of access points?
There are two limits, and the stricter one decides the result. The first is coverage: each Wi-Fi point covers only a certain area, after which the signal becomes too weak. The second is load. An access point shares its airtime among all devices that are transmitting at that moment, and beyond a certain number everything slows down for everyone, however good the reception.
The planner calculates both and takes the larger number. For coverage, it divides the area per floor by the area one unit covers with your type of construction. Concrete ceilings separate the floors, and each gets its own units; measurements in multi-storey buildings have shown that ceilings add their own, considerable attenuation since Seidel 1992. With timber joist ceilings, at the lower end of the range one unit may also serve the neighbouring floor. For load, it divides the simultaneously active devices by a guide value for each type of use.
An example: a brick-built detached house, two floors of 75 m² each, concrete ceilings. A Wi-Fi point covers 55 to 105 m² there, so each floor needs one or two units, two to four in total. The 20 phones, TVs and laptops in the house would manage with a single one. Here the area decides.
It is different in a training room. 120 m² of lightweight construction is enough for one, at most two access points. But if 60 people with laptops sit there in a video conference, it takes three to four, or the picture stutters. Here the load decides.
Why always a range? The lower number applies when the devices are in the middle and there are few walls in the way. The upper one applies to awkward layouts, long corridors and a router hanging at the edge. Where you end up only shows once the units are set up. Or in a measurement. Even the ITU’s indoor model only hits the mark once it has been adjusted to measured values from the specific building (Chrysikos 2009).
The planner’s rules at a glance
- Cell area per Wi-Fi point by building and construction (table in the next section). For video calls, 0.85 times that applies; for scanners and tills on the move, 0.7 times; for large mirror or glass surfaces, a further 0.9 times.
- Concrete ceilings or underfloor heating: each floor is calculated on its own. Timber joist or unknown ceilings: at the lower end, one unit may serve two floors. At the upper end, each floor has at least one unit.
- Capacity: simultaneously active devices divided by 30 to 50 (browsing), 15 to 25 (video calls) or 25 to 40 (scanners on the move), rounded up.
- Result: the larger number from coverage and capacity, at least one Wi-Fi point.
- Measurement mandatory for high-bay warehouses, workshops or halls with metal, scanners on the move, an outbuilding, and from 13 Wi-Fi points. Not necessary for a flat or house of up to 3 Wi-Fi points without metal. Otherwise recommended.
- Wired access points: one PoE+ port with 30 W on the switch per unit, plus one port to the router; cable no longer than 100 m. Whether the switch’s budget and ports are enough is shown by the PoE calculator.
03 / GUIDELINE VALUES
Why is the square metre figure alone not enough?
Radio loses strength with every metre, and every obstacle takes a little more away. This is measured in decibels (dB), on a logarithmic scale: 3 dB less means half the power, 10 dB a tenth, 20 dB a hundredth. In free space, every doubling of the distance costs 6 dB. A reinforced concrete wall takes 30 to 50 dB away in the 5 GHz band. That is equivalent to increasing the distance through free air from 1 to 30 m, often more.
On top of that, 5 GHz suffers much more from walls than 2.4 GHz. So the fast band is precisely the one that gets through walls worst.
| Obstacle | 2.4 GHz | 5 GHz | What that means |
|---|---|---|---|
| Uncoated glass | 2–4 | 3–7 | hardly an obstacle |
| Plasterboard or timber-frame wall | 3–6 | 5–10 | two or three walls are fine |
| Brick or sand-lime brick, 11.5 cm | 8–10 | 15–20 | after two walls it gets tight |
| Brick or sand-lime brick, 24 cm | 12–15 | 20–25 | one outside or cellar wall is enough |
| Reinforced concrete ceiling | 15–25 | 16–30 | every floor needs its own unit |
| Reinforced concrete wall, approx. 20 cm | 23–30 | 30–50 | practically a radio boundary |
| Insulating glass, metal-coated | 10–30 | 20–40 | little gets in from outside |
| Metal door, sheet-metal wall | 20–30 | 25–35 | acts like a mirror |
The ranges come from manufacturers’ data and planning tables and vary with thickness, moisture and reinforcement; fresh concrete attenuates more than dried-out concrete. For ceilings, the ITU-R P.1238 recommendation of the International Telecommunication Union gives 16 dB per ceiling in office buildings at 5.2 GHz. That is why the planner calculates each floor separately with concrete ceilings. And because attenuation cannot simply be added up per wall (Lott 2001), it works with cell areas per type of construction rather than counting walls.
Energy-efficient new builds are a special case: coated multiple glazing and thick walls attenuated on average 20 to 25 dB more than an old building in measurements (Rodriguez 2014). An access point in the yard hardly serves such a house from outside.
What area does one Wi-Fi point cover?
The following areas are values from experience for one Wi-Fi point when browsing and streaming, in each case from unfavourable to favourable. For video calls the planner uses 85 per cent of this area, for scanners and tills that switch Wi-Fi point while walking, 70 per cent. There the signal must still be strong at the edge of the cell.
| Building | Lightweight or timber | Brick or sand-lime brick | Reinforced concrete | Metal, racking, machinery |
|---|---|---|---|---|
| Flat, detached house | 80–150 | 55–105 | 35–70 | 30–55 |
| Office, practice or shop | 100–180 | 70–125 | 45–80 | 35–65 |
| Workshop or production hall | 400–700 | 400–700 | 360–630 | 240–420 |
| Warehouse with high-bay racking | 250–450 | 250–450 | 225–405 | 150–270 |
| Outdoor area or yard | 800–1,500, with a clear line of sight | |||
How many devices can one access point handle?
The figures on the packaging, often several hundred devices, are technical upper limits. As a planning figure for dense environments, Cisco Meraki gives about 25 active devices per radio, around 50 per access point. The planner works with 30 to 50 simultaneously active devices per Wi-Fi point for browsing, 15 to 25 for video calls and 25 to 40 for scanners on the move. What counts is what transmits at the same time, not what was ever logged in. How quickly a full network reaches its limit is shown by a measurement in a conference Wi-Fi: only about 40 per cent of the airtime went to useful data there, the rest to retransmissions (Rodrig 2005).
Guide values last checked on 13 November 2026.
04 / SETUP TYPE
Mesh or access points: what suits you?
Both spread the Wi-Fi across several devices under one network name. The difference lies in how the devices are connected to each other and who manages them.
Mesh over radio is the way without drilling. The units pass the signal on by radio, and every hop costs speed, because the link between them shares airtime with your devices. With a simple repeater, throughput roughly halves. An unplanned wireless mesh of 37 nodes reached on average 627 kbit/s over three hops (Bicket 2005); today’s devices are faster, but the principle remains. Mesh devices with their own radio band for the link between units lose less. For a flat or a house with two or three units, that is usually enough.
Mesh with cable, often called LAN backhaul, connects the units by network cable. That removes the loss of speed, and each unit can stand where it is needed instead of where the previous one only just reaches. If there is a cable or a conduit in the house, this is the better choice.
Access points on the ceiling are the setup for businesses. Each is connected to the switch by a cable, which supplies it with power over the same cable (Power over Ethernet, PoE for short). A port to IEEE 802.3at delivers up to 30 W. All devices are managed centrally so that network name, password, guest network and roaming are set the same everywhere. A cable may be up to 100 m long.
Which Wi-Fi standard?
| Standard | Standard | Frequency bands | Assessment |
|---|---|---|---|
| Wi-Fi 5 | 802.11ac | 5 GHz (plus 2.4 GHz with Wi-Fi 4) | still works, no longer choose it when buying new |
| Wi-Fi 6 | 802.11ax | 2.4 and 5 GHz | minimum when buying new, enough for most houses |
| Wi-Fi 6E | 802.11ax | 2.4, 5 and 6 GHz | worthwhile if many devices support 6 GHz |
| Wi-Fi 7 | 802.11be | 2.4, 5 and 6 GHz | for dense offices; devices often need more power over PoE |
Wi-Fi 6 was built specifically for more throughput per area in dense environments (Khorov 2019), which is why it is the minimum when buying new. The 6 GHz band has been open in Germany since July 2021: 480 MHz between 5945 and 6425 MHz. It is almost empty, but its range is shorter than 5 GHz and it only helps devices that support it. Access points with normal transmit power may only use it indoors. For the yard, that leaves 5 and 2.4 GHz.
05 / PLACEMENT
Where does the access point belong?
The best place is almost always the middle of the area the device is meant to serve, in the open and raised. The worst is where the router usually ends up: in the hallway at the house connection, in the cellar or in the cupboard under the TV.
- Ceiling or high shelf rather than floor. Radio spreads in all directions, and nobody sits below the device.
- Not in a cupboard, technical room or media box. Metal doors and distribution boxes shield the signal.
- Not behind a TV, mirror, radiator or aquarium. Metal reflects the signal, water absorbs it.
- Mesh units over radio go where the signal from the previous one is still strong, not into the dead spot itself. As a rule of thumb, about halfway between the router and the area without reception.
- On several floors, stagger them rather than placing them exactly above each other. Two devices right next to each other achieve nothing but interference.
- Do not leave the router in the cellar just because the line arrives there. A network cable brings it to a better spot.
To check, a phone and our speed test are enough: measure once in every room and note the values. Where it drops clearly, a Wi-Fi point is missing or in the wrong place. The guide Improving Wi-Fi at home covers this in more detail, with the typical mistakes at home. If you would rather have it done for you: we set up Wi-Fi in flats and houses, with cable where it pays off.
06 / HALL AND WAREHOUSE
What is different in a workshop, hall and warehouse?
In a hall, area is rarely the problem. One access point under the roof of an open workshop covers 400 to 700 m². The difficulty comes from metal and from devices that move and cannot wait.
Metal reflects the signal instead of letting it through. Machines, steel beams and racking create echoes and shadows that appear in no floor plan. A crane moves through the radio cell, a lorry stands in the gate, and the situation already looks different from yesterday. Measurements in industrial halls show exactly that: distinct propagation characteristics for each type of hall and a signal that fluctuates with operations (Tanghe 2008, Cheffena 2016). That is why, with metal, the planner counts on only 60 per cent of the hall area per device.
In a high-bay warehouse, the goods are an additional factor. Cardboard boxes attenuate little, drinks a lot, because water absorbs radio waves. An omnidirectional antenna under the roof mainly serves the tops of the racking; down in the narrow aisle, little arrives. The devices therefore belong in the aisles or get directional antennas that radiate into them deliberately.
Handheld scanners, forklift terminals and mobile tills are the most demanding. They switch from one access point to the next while moving (roaming), and every dropout costs a scan. Most of the time during a switch goes on searching for the next access point, and it varies greatly between manufacturers (Mishra 2003); the fast handover method 802.11r shortens it considerably (Bangolae 2006). For such networks Cisco assumes at least −67 dBm at every point and about 20 per cent overlap between radio cells. That makes the cells smaller, and the measurement becomes mandatory. What else goes wrong in the hall is covered in the guide Wi-Fi in workshops and warehouses.
If a side hall is to be included, there are two ways. A buried cable, between buildings preferably fibre, because it creates no electrical connection. Or a point-to-point wireless link with two devices that must see each other. Whether the line of sight is clear is decided in the yard, not at the desk.
07 / RESEARCH
What the research says
The planner’s guide values are values from experience, but they do not stand in a vacuum. The following six findings from radio and network research explain why it calculates the way it does.
- Ceilings are obstacles in their own right. Even the first series of measurements in multi-storey office buildings determined separate attenuation factors for each ceiling between transmitter and receiver (Seidel 1992). More walls and ceilings do not simply add up (Lott 2001).
- One slow device slows everyone. If a laptop at the edge of range transmits at a low rate, the throughput of all the others in the same cell drops roughly to its speed (Heusse 2003). That is why the planner plans cells whose edge still has good reception.
- More quiet access points beat a few loud ones. A plan that included interference between the devices delivered more throughput than the one with the smallest possible number of devices, and it relied on low transmit power (Bosio 2007). So the upper end of the range is no luxury.
- New builds shield the signal. Energy-efficient buildings attenuated from outside to inside on average 20 to 25 dB more than an old building (Rodriguez 2014). For yard and garden that means: the access point outside serves the outside, not the house.
- Halls have a radio environment of their own. Machines interfere, metal throws echoes, and the signal fluctuates with operations (Tanghe 2008, Cheffena 2016). That is why workshops and warehouses have their own cell areas and a duty to measure.
- Roaming depends on the end device. How long a device drops out during a switch varied greatly between manufacturers in measurements (Mishra 2003). With 802.11r the switch becomes considerably shorter (Bangolae 2006), provided scanner and access points both support it.
All 15 works, with source, finding and use in the planner, are listed below under Studies and sources.
08 / SITE SURVEY
What does a site survey measure on site?
A site survey answers the question the planner leaves open: exactly where the devices need to be installed. It runs in five steps.
- Clarify layout and use. Who works where with which device, where the forklift runs, where cables and conduits are.
- Measure what is there. The area is surveyed on foot with a measuring device: signal strength, sources of interference and the neighbours’ networks on all channels.
- Set up a test access point. A test device is installed at the planned locations, and the real range is measured. In the hall during operations, because empty racking gives different values from full racking.
- Fix the locations. The result is a plan with locations, cable routes and a parts list.
- Measure again after installation. Only the measurement afterwards shows that coverage is as planned.
We take on the planning and installation of access points, switches and cabling as part of our network technology for businesses. The effort depends on area and building; our hourly rates are openly listed on the price list, and we tell you in advance what a measurement at your premises costs.
Where the planner stops
- It does not know your floor plan. A long corridor and a square house of the same area need different numbers of devices.
- It cannot hear your neighbours. In blocks of flats and commercial areas, other people’s networks occupy the channels. Only a measurement shows that.
- It does not measure your connection. If too little arrives from the internet, another access point does not help. The speed test on the cable settles that; what is available in the Vogtland is listed under Internet in the Vogtland.
- It does not plan radio links. A point-to-point link to the neighbouring building needs a clear line of sight, and that is checked on site.
09 / FOR AI ASSISTANTS
Using this tool from an AI assistant
Assistants such as Claude or ChatGPT that speak the Model Context Protocol (MCP) can call this page’s calculation directly instead of rebuilding it. The server is public, needs no sign-in and stores nothing. The answer always includes the link to this page, the date of the data and the limits of the result.
- Endpoint
https://aureum-tech.com/mcp- Tool
werkzeug_wlan_planer- Transport
- Streamable HTTP, read-only
| Name | Required | Meaning |
|---|---|---|
gebaeude | yes | Building type: wohnung (flat), efh (detached, semi-detached or terraced house), buero (office), praxis (practice or shop), werkstatt (workshop or production hall), lager (warehouse with high-bay racking), aussen (yard, car park, garden). |
flaeche_m2 | yes | Area per floor in square metres; for an outdoor area, the whole area. |
etagen | no | Number of floors needing Wi-Fi, cellar and attic included. If omitted: the default for the building type. |
material | no | Predominant wall material: leicht (plasterboard, timber, prefabricated house), ziegel (brick, sand-lime brick), beton (reinforced concrete, prefabricated panel block), metall (steel hall, racking, machinery). |
decke | no | Ceilings between the floors: holz (timber joists), beton (concrete) or unbekannt (unknown). Unknown makes the range wider. |
geraete | no | Simultaneously active Wi-Fi devices (phones, laptops, TVs, scanners). Rule of thumb: two to three per person. |
nutzung | no | Main use: surfen (browsing, streaming), video (video calls, home working, calls over Wi-Fi), roaming (scanners, tills, devices that switch access point while walking). |
lan | no | Whether a network cable can be laid to the locations: ja (yes), teilweise (in part) or nein (no). |
fussbodenheizung | no | Underfloor heating present in the ceilings. |
glas | no | Large mirrors, glass walls or metal-coated insulating glass. |
nebengebaeude | no | An outbuilding (side hall, garage) is to be covered as well. |
Questions where an assistant should call it
- “How many access points do I need for a 1,500 m² warehouse with handheld scanners?”
- “Is a mesh system enough for a detached house with two floors of 80 m² each?”
- “How many Wi-Fi access points does a 300 m² office need with 25 people working from home?”
- “Our Wi-Fi in a prefabricated panel block (Plattenbau) does not reach the bedroom; how many mesh units do we need?”
How the connection works and what MCP can do in your own business is explained on the page about MCP integrations.
10 / COMMON QUESTIONS
Questions about Wi-Fi planning
How many access points do I need for 100 m²?
That depends on the walls. With lightweight partitions, one well-placed router or access point is usually enough for 100 m² on one floor, two if the layout is awkward. With brick or masonry, one unit covers about 55 to 105 m², so you need one or two. With reinforced concrete, for example in a prefabricated panel block (Plattenbau), one unit covers only 35 to 70 m²; two or three are realistic then. Every additional floor counts separately.
Is a mesh system enough for a detached house?
Usually yes. By our guide values, a brick house with two floors of 75 m² each needs two to four mesh units, counting the router. It runs most reliably when the units are connected by network cable (LAN backhaul). Linking them by radio works too, but then each unit needs good reception from the previous one at its location.
How many devices can one access point handle?
As a planning figure for dense environments, Cisco Meraki gives about 25 simultaneously active devices per radio, so around 50 per access point with two radios. For video calls we plan more cautiously, at 15 to 25 devices. The figures on the packaging, often several hundred, are technical upper limits and not values at which a network still runs smoothly.
What weakens Wi-Fi the most?
Metal and reinforced concrete. A reinforced concrete wall of about 20 cm absorbs 30 to 50 dB in the 5 GHz band, a plasterboard wall only 5 to 10 dB. Just 10 dB means a tenth of the power. Also strongly attenuating are metal-coated insulating glass, mirrors, aquariums and full drinks shelves, because water absorbs radio waves. With underfloor heating, there are pipes full of water and often metal layers in the ceiling as well.
Do I need Wi-Fi 7?
Only if your devices support it. Wi-Fi 6 is enough for most houses and workshops. Wi-Fi 6E and 7 also use the 6 GHz band, in Germany 480 MHz between 5945 and 6425 MHz. The band is almost empty, but its range is shorter than 5 GHz. In a busy office with new laptops it is worthwhile; in a hall with older handheld scanners it brings nothing.
Repeater or mesh: which is better?
A simple repeater receives and transmits in turn on the same radio link. Throughput roughly halves as a result, and with two repeaters in a row a quarter is left. Mesh systems manage all units together, steer devices to the better unit and often have their own radio band for the link between units. In both cases the best option is a network cable to the second device.
When does the Wi-Fi need to be measured on site?
Always when devices switch access points while moving, such as scanners in a warehouse, and always with halls containing metal, with racking warehouses and with radio links to an outbuilding. For uninterrupted roaming, Cisco assumes at least −67 dBm at every point and about 20 per cent overlap between radio cells. Only a measurement shows whether that is achieved, not a calculation.
11 / STUDIES AND SOURCES
What the tool is based on
The guide values and notes above are based on these 15 scientific papers. Each one has been checked via its DOI or the publisher’s page (most recently on 13 November 2026): it exists, it has not been retracted, and its findings still hold for this question today.
Seidel, S. Y.; Rappaport, T. S. (1992): 914 MHz path loss prediction models for indoor wireless communications in multifloored buildings. IEEE Transactions on Antennas and Propagation 40 (2), pp. 207–217
Finding Measurements in multi-storey office buildings: walls, partitions and ceilings can be described as additional attenuation per obstacle, and separate attenuation factors were determined for up to four ceilings. The prediction was accurate to within 6 dB at most measuring points.
In the tool The basis for the planner treating ceilings as an attenuator in their own right and calculating floors separately.
doi.org/10.1109/8.127405 · Journal article
Lott, M.; Forkel, I. (2001): A multi-wall-and-floor model for indoor radio propagation. IEEE VTS 53rd Vehicular Technology Conference (VTC 2001 Spring), Vol. 1, pp. 464–468
Finding Total attenuation does not grow linearly with the number of walls and ceilings penetrated. The model provides parameters for 5.2 GHz and was compared with measurements.
In the tool Explains why the planner does not simply add up attenuation per wall but works with cell areas per type of construction.
doi.org/10.1109/VETECS.2001.944886 · Conference paper
Chrysikos, T.; Georgopoulos, G.; Kotsopoulos, S. (2009): Site-specific validation of ITU indoor path loss model at 2.4 GHz. 2009 IEEE International Symposium on a World of Wireless, Mobile and Multimedia Networks (WoWMoM), pp. 1–6
Finding The ITU’s general indoor model (P.1238) only fitted after it had been adjusted to measured values from the specific office building; the paper provides parameters for 2.4 GHz.
In the tool Explains why the planner gives a range and refers the exact number to a measurement in the building.
doi.org/10.1109/WOWMOM.2009.5282432 · Conference paper
Durgin, G.; Rappaport, T. S.; Xu, H. (1998): Measurements and models for radio path loss and penetration loss in and around homes and trees at 5.85 GHz. IEEE Transactions on Communications 46 (11), pp. 1484–1496
Finding Measurement campaign at three houses and two groups of trees at 5.85 GHz: trees and house walls each add their own measurable attenuation on top of the free-space path.
In the tool Note for outdoor areas that trees and buildings between access point and device shorten the range.
doi.org/10.1109/26.729393 · Journal article
Rodriguez, I.; Nguyen, H. C.; Jorgensen, N. T. K., et al. (2014): Radio Propagation into Modern Buildings: Attenuation Measurements in the Range from 800 MHz to 18 GHz. 2014 IEEE 80th Vehicular Technology Conference (VTC2014-Fall), pp. 1–5
Finding Energy-efficient new builds with coated multiple glazing and thick walls attenuated on average 20 to 25 dB more than an old building, which stayed below 10 dB. Attenuation rose with frequency.
In the tool Supports the insulating glass row in the attenuation table and the reduction for large glass surfaces.
doi.org/10.1109/VTCFall.2014.6966147 · Conference paper
Tanghe, E.; Joseph, W.; Verloock, L., et al. (2008): The industrial indoor channel: large-scale and temporal fading at 900, 2400, and 5200 MHz. IEEE Transactions on Wireless Communications 7 (7), pp. 2740–2751
Finding Industrial halls behave differently from flats and offices in radio terms and must be classified by their surroundings. Besides attenuation, the signal fluctuates over time there, because things move in the hall.
In the tool Halls get their own cell areas in the planner, and the measurement should take place during operations.
doi.org/10.1109/TWC.2008.070143 · Journal article
Cheffena, M. (2016): Propagation Channel Characteristics of Industrial Wireless Sensor Networks [Wireless Corner]. IEEE Antennas and Propagation Magazine 58 (1), pp. 66–73
Finding Overview of radio propagation in industry: large machines cause interference, strongly reflective metal surfaces create many signal paths, and conditions change with operations.
In the tool Explains the reduction for metal in halls and the requirement to measure in metal halls.
doi.org/10.1109/MAP.2015.2501227 · Review
Bianchi, G. (2000): Performance analysis of the IEEE 802.11 distributed coordination function. IEEE Journal on Selected Areas in Communications 18 (3), pp. 535–547
Finding Analytical model of the Wi-Fi access method: all devices in a radio cell share one medium, and the achievable throughput depends on the number of devices wanting to transmit.
In the tool Basis of the capacity limit: devices divided by devices per Wi-Fi point.
doi.org/10.1109/49.840210 · Journal article
Heusse, M.; Rousseau, F.; Berger-Sabbatel, G., et al. (2003): Performance anomaly of 802.11b. IEEE INFOCOM 2003, Vol. 2, pp. 836–843
Finding A single device that transmits slowly because of weak reception pulls the throughput of all the others in the same cell down to roughly its own speed, because the access method gives everyone the same number of transmission turns.
In the tool The planner works with cells whose edge still has good reception, instead of placing devices at the limit of range.
doi.org/10.1109/INFCOM.2003.1208921 · Conference paper
Rodrig, M.; Reis, C.; Mahajan, R., et al. (2005): Measurement-based characterization of 802.11 in a hotspot setting. ACM SIGCOMM Workshop on Experimental Approaches to Wireless Network Design and Analysis (E-WIND 2005), pp. 5 ff.
Finding In a fully occupied conference Wi-Fi, only about 40 per cent of the airtime went to actual user data, the rest mainly to retransmissions after collisions and transmission errors.
In the tool Explains why the planner works with 15 to 50 active devices per Wi-Fi point and not with the hundreds in the data sheet.
doi.org/10.1145/1080148.1080150 · Conference paper
Mishra, A.; Shin, M.; Arbaugh, W. (2003): An empirical analysis of the IEEE 802.11 MAC layer handoff process. ACM SIGCOMM Computer Communication Review 33 (2), pp. 93–102
Finding When switching between access points, it is mainly the search for the next device that takes time, enough for noticeable dropouts. The duration varied greatly between manufacturers.
In the tool For scanners and tills on the move, the planner calls for a measurement and for devices that handle fast roaming.
doi.org/10.1145/956981.956990 · Journal article
Bangolae, S.; Bell, C.; Qi, E. (2006): Performance study of fast BSS transition using IEEE 802.11r. Proceedings of the 2006 International Conference on Wireless Communications and Mobile Computing (IWCMC), pp. 737–742
Finding With the fast handover method 802.11r, the transition between two access points became considerably shorter for a voice application, and fewer packets were lost.
In the tool Supports the recommendation to look for 802.11k, v and r for devices on the move.
doi.org/10.1145/1143549.1143696 · Conference paper
Bicket, J.; Aguayo, D.; Biswas, S., et al. (2005): Architecture and evaluation of an unplanned 802.11b mesh network. Proceedings of the 11th Annual International Conference on Mobile Computing and Networking (MobiCom 2005), pp. 31–42
Finding An unplanned wireless mesh of 37 nodes delivered usable but limited performance: on average 627 kbit/s between two nodes over an average of three radio hops.
In the tool Supports the note that mesh over radio works without drilling, but every radio hop costs speed.
doi.org/10.1145/1080829.1080833 · Conference paper
Bosio, S.; Capone, A.; Cesana, M. (2007): Radio Planning of Wireless Local Area Networks. IEEE/ACM Transactions on Networking 15 (6), pp. 1414–1427
Finding A plan that took interference between access points and the access method into account achieved more throughput than planning for the smallest possible number of devices; access points with low transmit power were preferred.
In the tool Explains why the upper end of the range is no luxury: more devices with less transmit power beat a few loud ones.
doi.org/10.1109/TNET.2007.896478 · Journal article
Khorov, E.; Kiryanov, A.; Lyakhov, A., et al. (2019): A Tutorial on IEEE 802.11ax High Efficiency WLANs. IEEE Communications Surveys & Tutorials 21 (1), pp. 197–216
Finding Wi-Fi 6 (802.11ax) aims at more throughput per area in dense environments, among other things by splitting one channel among several devices at once (OFDMA) and by better reuse of channels.
In the tool Explains Wi-Fi 6 as the minimum when buying new, especially where many devices transmit at the same time.
doi.org/10.1109/COMST.2018.2871099 · Review
Standards, authorities and manufacturer data
- Recommendation ITU-R P.1238: Propagation indoors · International Telecommunication Union
- Understand Site Survey Guidelines for WLAN Deployment · Cisco
- High Density Wi-Fi Deployment Guide · Cisco Meraki
- WLAN-Nutzungen im 6-GHz-Bereich, press release of 14.07.2021 · Bundesnetzagentur
12 / MORE TOOLS
More free tools
- AT-W2 · Home & business
Windows 10 check
Does this PC still get security updates, and what needs doing by October 2027? - AT-W4 · Businesses
IT emergency check
How quickly could your business get back to work after an outage? - AT-W5 · Businesses
E-mail check
Are your e-mails landing in spam? Your domain’s SPF, DKIM and DMARC in plain language. - AT-W6 · Businesses
UPS calculator
Which UPS keeps your server, router and till running long enough during a power cut? - AT-W7 · Home
Digital legacy planning sheet
Which accounts, devices and contracts should your family know about? - AT-W8 · Businesses
XRechnung viewer
Received an XRechnung as an XML file? This makes it readable without the file leaving your computer.
The range is set, but not the locations. We measure at your premises, in a house as in a hall, and tell you in advance what the measurement costs. We are based in Rodewisch and measure throughout the Vogtland.
+49 3744 4399760[email protected]Mon–Fri 8:00–17:00 · Straße der Jugend 5, 08228 Rodewisch