Electricity cost calculator: what do a PC, server and NAS cost per year?
How much electricity a device needs comes from its power times its running time, and running time decides: a small server that runs around the clock uses more in a year than three office PCs with monitors put together. The calculator takes values for load, idle and standby from Energy Star and manufacturer data sheets and shows the biggest items. In the example office it adds up to 1,227 kWh a year, around €458. You also see when a more efficient device pays for itself.
- free
- no sign-up
- runs in your browser
01 / CALCULATOR
Enter devices, read off consumption and cost
Calculator · Device list, costs and CO₂
Guide values. The templates are averages from Energy Star, data sheets and experience; your device may differ considerably. A measured value is always better.
Runs in your browser. Nothing is sent or stored.
02 / DEVICE VALUES
What IT devices use per year
A device has three states. Under load it is working, when idle it is switched on and waiting, in standby it sleeps or is off but still on the mains. How much it needs in a year depends less on the peak than on how long it spends in each state. A server mostly works at only 10 to 50 percent utilisation, yet even with almost no work it still draws about half of its full power Barroso and Hölzle 2007. That is why the idle figure is the most important number for devices that run all the time.
The values in the calculator are not rating-plate figures. A rating plate shows what the power supply can deliver at most, and even when planning data centres such figures are of limited use, because consumption varies strongly with the work done Fan et al. 2007. If you enter more than 1,000 W per device, you therefore get a query. For PCs, monitors and servers, idle and standby come from the Energy Star data sets: each is the median of all certified models, as of 13 November 2026. Routers, switches, access points and NAS are listed with manufacturers’ data sheet values. Anything marked “estimate” is based on our experience.
The calculation goes device by device, with power per state and running time. This bottom-up method matches the measured consumption of offices much better than flat values per workstation Menezes et al. 2014. When a device is on, the calculator uses idle plus utilisation times the gap to load. That is the simplest of the common consumption models, and how accurate such models are is often an open question in research too Dayarathna et al. 2016.
| Device | Load | Idle | Standby | Usage | kWh | Euro | Source |
|---|---|---|---|---|---|---|---|
| Office PC, newer model | 60 W | 10,5 W | 1.6 W | 8 h a day, 5 days | 53 | 20 € | Idle and sleep mode: Energy Star median of certified models, as of 13.11.2026 · Estimate: load, usage |
| Office PC, older (before about 2016) | 90 W | 40 W | 3 W | 8 h a day, 5 days | 124 | 46 € | Figure from experience · Estimate: load, idle, standby, usage |
| Mini PC or thin client | 25 W | 4,7 W | 0,8 W | 8 h a day, 5 days | 24 | 8,81 € | Idle and sleep mode: Energy Star median of certified models, as of 13.11.2026 (thin clients) · Estimate: load, usage |
| Laptop on mains power | 30 W | 4,9 W | 0,6 W | 8 h a day, 5 days | 25 | 9,21 € | Idle and sleep mode: Energy Star median of certified models, as of 13.11.2026 · Estimate: load, usage |
| All-in-one PC with screen | 60 W | 15,9 W | 2 W | 8 h a day, 5 days | 65 | 24 € | Idle and sleep mode: Energy Star median of certified models, as of 13.11.2026 · Estimate: load, usage |
| Workstation (CAD, graphics) | 250 W | 70,1 W | 4,3 W | 8 h a day, 5 days | 250 | 93 € | Idle and sleep mode: Energy Star median of certified models, as of 13.11.2026 · Estimate: load, usage |
| Monitor, 24 inch | 12,9 W | 12,9 W | 0,2 W | 8 h a day, 5 days | 28 | 11 € | Operation and sleep mode: Energy Star median of certified models, as of 13.11.2026 (23 to 25 inch) · Estimate: usage |
| Monitor, 27 inch | 16,9 W | 16,9 W | 0,2 W | 8 h a day, 5 days | 37 | 14 € | Operation and sleep mode: Energy Star median of certified models, as of 13.11.2026 (26.5 to 28.9 inch) · Estimate: usage |
| Monitor, 32 inch | 27,7 W | 27,7 W | 0,4 W | 8 h a day, 5 days | 60 | 23 € | Operation and sleep mode: Energy Star median of certified models, as of 13.11.2026 (29 to 32.9 inch) · Estimate: usage |
| Laser printer or multifunction device | 3,3 W | 3,3 W | 3,3 W | around the clock | 29 | 11 € | Average from the Energy Star weekly TEC value (median 0.55 kWh, black-and-white laser) |
| Router (e.g. FRITZ!Box 7530 AX) | 6 W | 6 W | 6 W | around the clock | 53 | 20 € | AVM data sheet: average power consumption 6 W |
| Router with telephony (e.g. FRITZ!Box 7590 AX) | 15 W | 15 W | 15 W | around the clock | 131 | 49 € | AVM data sheet: 14 to 16 W on average |
| Fibre modem (ONT) | 6 W | 6 W | 6 W | around the clock | 53 | 20 € | Figure from experience · Estimate: load, idle, standby |
| Switch, 8 ports | 3,3 W | 3,3 W | 3,3 W | around the clock | 29 | 11 € | TP-Link TL-SG108: 3.31 W at most according to the data sheet |
| Switch, 24 ports | 13,6 W | 13,6 W | 13,6 W | around the clock | 119 | 44 € | TP-Link TL-SG1024D: 13.62 W at most according to the data sheet |
| Wi-Fi access point Wi-Fi 6 (PoE) | 13,7 W | 13,7 W | 13,7 W | around the clock | 120 | 45 € | Omada EAP610: 13.7 W at most over PoE according to the data sheet |
| Firewall (desktop unit) | 20 W | 20 W | 20 W | around the clock | 175 | 65 € | Figure from experience · Estimate: load, idle, standby |
| Phone system | 25 W | 25 W | 25 W | around the clock | 219 | 82 € | Figure from experience · Estimate: load, idle, standby |
| IP phone (PoE) | 4 W | 4 W | 4 W | around the clock | 35 | 13 € | Figure from experience · Estimate: load, idle, standby |
| IP camera (PoE) | 7 W | 7 W | 7 W | around the clock | 61 | 23 € | Figure from experience · Estimate: load, idle, standby |
| NAS with 2 drives (e.g. Synology DS224+) | 14,7 W | 14,7 W | 4,4 W | around the clock | 129 | 48 € | Synology: 14.69 W during access, 4.41 W with drives in sleep mode |
| NAS with 4 drives (e.g. Synology DS923+) | 35,5 W | 35,5 W | 11,5 W | around the clock | 311 | 116 € | Synology: 35.51 W during access, 11.52 W with drives in sleep mode |
| Tower server, 1 processor | 120 W | 51,9 W | 5 W | around the clock | 574 | 214 € | Idle: Energy Star median of certified models, as of 13.11.2026 (SERT, 1 socket, tower) · Estimate: load, standby, usage |
| Rack server, 1 processor | 200 W | 128,3 W | 8 W | around the clock | 1.250 | 466 € | Idle: Energy Star median of certified models, as of 13.11.2026 (SERT, 1 socket, rack) · Estimate: load, standby, usage |
| Rack server, 2 processors | 350 W | 185,9 W | 10 W | around the clock | 1.916 | 715 € | Idle: Energy Star median of certified models, as of 13.11.2026 (SERT, 2 sockets, rack) · Estimate: load, standby, usage |
Workstation devices at 20 % utilisation, servers likewise. Energy Star data sets retrieved on 14 November 2026; data sheets from AVM, TP-Link, Omada and Synology; dates are listed in the sources.
Fig. 1 · The calculator’s preset: 82 % of the electricity is base load of devices that are switched on, meaning idle and power supplies in continuous operation; only 15 % comes from load.
Network and standby: small, but never off
Routers, switches and access points draw little, but for 8,760 hours a year, and their consumption hardly depends on the amount of data. In the USA, network devices used around 1 percent of the electricity in buildings in 2008; the biggest items were switches in office buildings and the devices in homes Lanzisera et al. 2012. In measurements in ten homes, the standby of all devices alone accounted for 5 to 26 percent of yearly consumption Ross and Meier 2002.
Since then the EU has tightened the rules. Since 2025, new household and office devices may draw no more than 0.5 W in standby and off mode, or 0.8 W with a status or information display; from 2027 the off mode drops to 0.3 W. For networked standby the limit since 2025 is 2 W; only devices with high network availability may draw 8 W, and from 2027 7 W (Regulation (EU) 2023/826, according to the European Commission). A monitor in standby therefore hardly matters any more; an older power supply sitting warm on the desk matters more. For printers the calculator uses the weekly TEC value from the data sheet, which includes printing, standby and sleep mode; how laser and inkjet compare otherwise is covered in the guide Buying a printer: inkjet or laser.
03 / PRICE AND CO₂
Electricity price and CO₂ factor: where the values come from
The preset is the average price for households from the BDEW electricity price analysis of October 2026. It applies to 3,500 kWh a year, includes a share of the standing charge and VAT, and is based on tariffs that can be newly signed. The value is 37.3 ct per kWh. Small businesses without a special contract pay a similar amount, but deduct the VAT as input VAT and calculate net at around 31.3 ct. According to BDEW, small and medium-sized industrial businesses with supply contracts from 160,000 kWh were at 17.9 cents.
Strictly speaking, only the unit price (Arbeitspreis) counts for a saving, that is the price per additional kilowatt-hour. The standing charge stays even when a device is off. It is therefore best to enter the unit price from your bill. Older contracts are often above the average of new tariffs.
The CO₂ figure comes from the Umweltbundesamt. For 2025 it estimates the direct emission factor of the German electricity mix at 344 g CO₂ per kWh, after 353 g in 2024. If you add methane and nitrous oxide as well as the upstream chain, meaning fuel extraction and power plant construction, it is 406 g CO₂ equivalents.
Both values are averages across all power plants. What a saved kilowatt-hour actually avoids depends on which power plant runs less because of it; in Great Britain this marginal value was clearly above the average Hawkes 2010. The CO₂ saving in the calculator is therefore on the cautious side.
| Parameter | Value | Source, date |
|---|---|---|
| CO₂, electricity mix 2025 (direct, preset) | 344 g/kWh | UBA, March 2026, estimated |
| CO₂, electricity mix 2024 | 353 g/kWh | UBA, provisional |
| Greenhouse gases with upstream chain 2025 | 406 g/kWh | UBA, CO₂ equivalents |
| Electricity price for households 2026 (preset) | 37,3 ct | BDEW, October 2026, incl. VAT |
| The same price net | 31,3 ct | without 19 % VAT, for businesses |
| Industry, 160,000 kWh to 20 million kWh | 17,9 ct | BDEW, October 2026 |
04 / OLD VS NEW
When a more efficient device pays off
Computing power per kilowatt-hour has roughly doubled every year and a half over decades Koomey et al. 2011, and even in data centres efficiency gains have largely absorbed the growing demand Masanet et al. 2020. A new device therefore almost always needs less electricity for the same work. Whether the swap pays off is still a separate question: the yearly saving times the service life gives the maximum amount the swap may cost.
| Swap | Usage | kWh less | CO₂ less | Euro per year | may cost (5 yrs) |
|---|---|---|---|---|---|
| Office PC, older (before about 2016) → Office PC, newer model | 8 h a day, 5 days | 71 | 24 kg | 27 € | 133 € |
| Office PC, older (before about 2016) → Mini PC or thin client | 8 h a day, 5 days | 101 | 35 kg | 38 € | 188 € |
| Rack server, 2 processors → Rack server, 1 processor | around the clock | 666 | 229 kg | 249 € | 1.243 € |
| Router with telephony (e.g. FRITZ!Box 7590 AX) → Router (e.g. FRITZ!Box 7530 AX) | around the clock | 79 | 27 kg | 29 € | 147 € |
The older office PC is an estimate. If you want to work out a swap properly, measure the old device for a week.
The table shows the pattern. For workstations with office hours the saving stays small, because the PC sleeps for most of the year. For devices that run around the clock it becomes noticeable, and it brings the most when one new server replaces two or three old ones. How we consolidate and virtualise servers is described under Servers and virtualisation.
Manufacturing counts too
A new device already has its CO₂ footprint before it is switched on. In a life-cycle assessment of eleven IT devices, these emissions were closely tied to mass; newer devices caused 50 to 60 percent less than older ones with a similar function Teehan and Kandlikar 2013. Anyone who keeps using a working laptop for longer or buys one second-hand clearly reduces the environmental impact, because so much is bound up in the components André et al. 2019. In the calculator you can enter the manufacturer’s figure; many manufacturers publish it as the “Product Carbon Footprint”. You then see after how many years the lower consumption makes up for the manufacturing.
Our rule of thumb: a workstation PC is replaced when it is due, for example because support ends or it becomes too slow, and then deliberately with an efficient model. Whether repairing an older device is still worthwhile is worked out by Repair or buy new; how it is written off for tax is covered by the IT depreciation calculator. If the old device is passed on, everything should be securely erased first, as described in the guide Disposing of an old PC.
05 / SAVING
How to reduce the electricity use of your IT
- Measure first. An energy meter plug shows in a week what a device really draws. Feedback on your own consumption demonstrably changes behaviour, whereas information alone hardly does Abrahamse et al. 2005.
- Switch on the power plan. In night-time walk-throughs of 16 offices, schools and practices, only one in seventeen desktop PCs went into power-saving mode by itself, and simply switching off would have brought consumption below 40 percent Webber et al. 2006. Sleep mode after 15 to 30 minutes, screen off after 10 minutes; in businesses this is set centrally, see Office PCs & laptops.
- Wake instead of leaving on. Updates and remote support are no reason to leave PCs on at night. Wake-on-LAN wakes them when needed; the network chip keeps the connection while the computer sleeps Nordman and Christensen 2010.
- Schedules for devices that run all the time. The NAS can stop its drives at night or switch off completely, access points can be switched off with a PoE schedule, and the FRITZ!Box has a Wi-Fi night switch. This does not affect the battery of a UPS, and the NAS and RAID calculator works out the storage size of the NAS.
- Consolidate servers. Every server draws a large part of its full load even without work Barroso and Hölzle 2007. If two or three small servers run side by side, one virtualised machine saves this base load several times over.
- Cut standby. A switchable power strip at the workstation disconnects the monitor, speakers and chargers completely from the mains after work.
- When buying, look at idle. For devices that run a lot, the idle figure on the data sheet matters more than the peak. Energy Star publishes it for certified PCs, monitors and servers.
Where the calculator stops
- Guide values instead of measurement. The templates are medians of certified models, data sheet values or marked estimates. Your device may be about half above or below these values.
- Simple model. When a device is on, the tool calculates linearly between idle and load. It does not capture short peaks, inrush currents and power supply losses at very low load.
- Average price. Calculated with a share of the standing charge; for savings, the unit price (Arbeitspreis) on your bill is what counts.
- Average CO₂. Electricity mix as a yearly average; the manufacturing of new devices only if you enter it.
If you want to know exactly, we measure the consumption of your devices, consolidate servers and replace power guzzlers where it pays off. We procure efficient devices through hardware ordering.
06 / FOR AI ASSISTANTS
Using this tool from an AI assistant
Assistants such as Claude or ChatGPT that speak the Model Context Protocol (MCP) can call this page’s calculation directly instead of rebuilding it. The server is public, needs no sign-in and stores nothing. The answer always includes the link to this page, the date of the data and the limits of the result.
- Endpoint
https://aureum-tech.com/mcp- Tool
werkzeug_stromkosten_rechner- Transport
- Streamable HTTP, read-only
| Name | Required | Meaning |
|---|---|---|
geraete | yes | Device list. Each device with a template or its own wattage values, e.g. [{"vorlage":"pc","anzahl":3},{"vorlage":"tower"}]. |
strompreis_ct | no | Unit price in cents per kWh. If omitted, 37.3 (BDEW electricity price analysis October 2026, 2026 average for households (3,500 kWh, standing charge pro rata, incl. VAT)). Businesses that deduct input VAT calculate net. |
co2_g_kwh | no | CO₂ in grams per kWh. If omitted, 344 (UBA, electricity mix 2025); with upstream chain 406. |
vergleich | no | Optional: comparison of old and new with savings and payback. |
Questions where an assistant should call it
- “What does a server that runs around the clock cost in electricity per year?”
- “How much electricity do three office PCs with monitors, a NAS and a FRITZ!Box use per year?”
- “Is it worth replacing an old office PC with a mini PC if that costs 500 euros?”
- “How much CO₂ does my NAS cause per year, and what does drive sleep mode save?”
How the connection works and what MCP can do in your own business is explained on the page about MCP integrations.
07 / COMMON QUESTIONS
Common questions about electricity use and electricity costs
How much electricity does a PC use per year?
A newer office PC used 8 hours a day on 5 days a week needs around 53 kWh a year; certified devices draw only 10.5 W on average when idle. An older PC with the same use comes to more like 124 kWh, and if you leave the newer one running around the clock it ends up at 179 kWh. At 37.3 ct per kWh that is €20, €46 and €67 a year.
What does a server cost in electricity per year?
A server runs around the clock, so 8,760 hours a year, and even with no work to do it draws a large part of its full load. A tower server with one processor therefore needs around 574 kWh a year, a rack server with two processors around 1,916 kWh. That is €214 and €715 a year. Consolidating several old servers onto one new one usually saves more than any other step.
How much electricity does a FRITZ!Box use?
According to the AVM data sheet, a FRITZ!Box 7530 AX draws 6 W on average, and a FRITZ!Box 7590 AX with telephony and DECT 14 to 16 W. Around the clock that is 53 kWh and 131 kWh a year, or €20 and €49. The Wi-Fi night switch saves only part of that, because phone and internet keep running.
How much electricity does a NAS use?
Synology gives 14.69 W during access and 4.41 W with the drives in sleep mode for a two-drive NAS (DS224+). If the drives run all the time, that is 129 kWh a year; with 8 hours of sleep mode every night it is 99 kWh. That comes to €48 and €37 a year; you then schedule the backup for the hours before sleep mode.
Is it worth replacing an old PC because of its electricity use?
Rarely on electricity alone. A newer office PC saves around 71 kWh a year compared with an older one at office hours, and making the new device causes CO₂ of its own. For the swap to pay for itself through electricity within 5 years, it could cost no more than €133. It looks different for devices that run around the clock, or if the PC is due for replacement anyway. Then it is worth checking the idle figure on the data sheet.
Which electricity price and which CO₂ figure are set?
The electricity price is the 2026 average for households from the BDEW electricity price analysis of October 2026, including VAT (MwSt.) and a share of the standing charge. The CO₂ figure is the emission factor of the German electricity mix for 2025 according to the Umweltbundesamt. The preset values are 37.3 ct per kWh and 344 g CO₂ per kWh; businesses that can deduct input VAT (Vorsteuer) calculate net, at around 31.3 ct. You can change both.
What is the difference between idle and standby?
Idle means the device is switched on and ready but not working, such as a PC showing the desktop. Standby means sleep mode, standby or switched off with the plug still in the socket. Since 2025, new household and office devices may draw no more than 0.5 W in standby and off mode, or 0.8 W with a display (Regulation (EU) 2023/826). PCs and servers have rules of their own.
Where does the electricity cost calculator stop?
It works with guide values per device and a simple model between idle and load. Only a measurement shows what your devices really draw. We measure the consumption of your devices on site in Rodewisch and across the Vogtland, consolidate servers and replace power-hungry devices where it pays off.
08 / STUDIES AND SOURCES
What the tool is based on
The guide values and notes above are based on these 14 scientific papers. Each one has been checked via its DOI or the publisher’s page (most recently on 14 November 2026): it exists, it has not been retracted, and its findings still hold for this question today.
Barroso, L. A.; Hölzle, U. (2007): The Case for Energy-Proportional Computing. Computer (IEEE), 40 (12), pp. 33–37
Finding Servers are seldom idle and seldom at full load, mostly between 10 and 50 % utilisation. Even an efficient server with almost no work still draws about half of its full power.
In the tool The server templates have their own idle value, utilisation is preset to 20 %, and with several servers the calculator advises consolidating them.
doi.org/10.1109/MC.2007.443 · Journal article
Fan, X.; Weber, W.-D.; Barroso, L. A. (2007): Power provisioning for a warehouse-sized computer. Proceedings of the 34th Annual International Symposium on Computer Architecture (ISCA), pp. 13–23
Finding Anyone planning electricity for many servers faces two uncertainties: the power ratings of the devices are of limited use, and consumption varies strongly with the actual computing work.
In the tool The templates are operating values, not rating-plate values, and above 1000 W per device the calculator asks whether the rating plate was copied.
doi.org/10.1145/1250662.1250665 · Conference paper
Dayarathna, M.; Wen, Y.; Fan, R. (2016): Data Center Energy Consumption Modeling: A Survey. IEEE Communications Surveys & Tutorials, 18 (1), pp. 732–794
Finding Review of more than 200 consumption models for data centres and their components. Many models rely on a few variables such as processor utilisation, and how accurate they are is often an open question.
In the tool The calculator uses the simplest of these models, idle plus utilisation times the gap to load, and describes it as an approximation in the limitations.
doi.org/10.1109/COMST.2015.2481183 · Review
Lanzisera, S.; Nordman, B.; Brown, R. E. (2012): Data network equipment energy use and savings potential in buildings. Energy Efficiency, 5 (2), pp. 149–162
Finding In 2008, network devices in the USA used around 18 TWh, about 1 % of the electricity in buildings. The biggest items were switches in office buildings (40 %) and devices in homes (30 %); efficient technology could save 20 to 50 %.
In the tool Router, switch and access point are in the list with their own data sheet values for continuous operation, and for access points the calculator suggests a schedule.
doi.org/10.1007/s12053-011-9136-4 · Journal article
Ross, J. P.; Meier, A. (2002): Measurements of whole-house standby power consumption in California homes. Energy, 27 (9), pp. 861–868
Finding In ten homes, the devices in standby together drew 14 to 169 W, 67 W on average, which was 5 to 26 % of yearly consumption. Devices with the same task differed greatly in standby.
In the tool Standby is a column of its own in the calculator, and from a 10 % share of consumption it suggests a switchable power strip.
doi.org/10.1016/S0360-5442(02)00023-3 · Journal article
Webber, C. A.; Roberson, J. A.; McWhinney, M. C. et al. (2006): After-hours power status of office equipment in the USA. Energy, 31 (14), pp. 2823–2838
Finding Night-time walk-throughs of 16 offices, schools and practices: most types of device were switched off less than half the time, and only 6 % of desktop PCs went into power-saving mode by themselves. If the devices were switched off at night, their consumption would fall to under 40 % according to the authors’ extrapolation (factor 2.6).
In the tool If a workstation device runs for more than 10 hours a day, the calculator works out what the power plan or switching off would bring.
doi.org/10.1016/j.energy.2005.11.007 · Journal article
Nordman, B.; Christensen, K. (2010): Proxying: The Next Step in Reducing IT Energy Use. Computer (IEEE), 43 (1), pp. 91–93
Finding A low-power proxy, for example in the network chip, keeps the connection to the network while the PC sleeps. That way a computer can rest without disappearing from the network.
In the tool Gives the reason for the advice to wake PCs for remote support and updates with Wake-on-LAN instead of leaving them running at night.
doi.org/10.1109/MC.2010.21 · Journal article
Koomey, J.; Berard, S.; Sanchez, M.; Wong, H. (2011): Implications of Historical Trends in the Electrical Efficiency of Computing. IEEE Annals of the History of Computing, 33 (3), pp. 46–54
Finding Computing power per kilowatt-hour has roughly doubled every year and a half over more than six decades.
In the tool This is why there is a comparison of old and new, and older PCs have a template of their own with higher values.
doi.org/10.1109/MAHC.2010.28 · Journal article
Masanet, E.; Shehabi, A.; Lei, N. et al. (2020): Recalibrating global data center energy-use estimates. Science, 367 (6481), pp. 984–986
Finding The electricity demand of data centres has grown more slowly than often predicted, because strong efficiency gains have largely absorbed the extra demand.
In the tool Supports the comparison for servers: a new server usually does the same work with less electricity, especially when it replaces several old ones.
doi.org/10.1126/science.aba3758 · Journal article
Teehan, P.; Kandlikar, M. (2013): Comparing Embodied Greenhouse Gas Emissions of Modern Computing and Electronics Products. Environmental Science & Technology, 47 (9), pp. 3997–4003
Finding Life-cycle assessment of the manufacture of eleven IT devices, including desktop PCs, laptops, a thin client, a monitor, a server and a switch. Emissions are closely tied to mass; newer devices caused 50 to 60 % less than older ones with a similar function.
In the tool In the comparison you can enter the manufacturing of the new device; the calculator then states after how many years the lower consumption has made up for it.
doi.org/10.1021/es303012r · Journal article
André, H.; Ljunggren Söderman, M.; Nordelöf, A. (2019): Resource and environmental impacts of using second-hand laptop computers: A case study of commercial reuse. Waste Management, 88, pp. 268–279
Finding Used laptops from commercial refurbishment instead of new ones: the longer use clearly reduced all environmental impacts examined, because so much is bound up in the components. The effort for testing and shipping hardly mattered.
In the tool Gives the reason for the advice not to replace a working device on electricity grounds alone, and for the advice to pass devices on rather than throw them away.
doi.org/10.1016/j.wasman.2019.03.050 · Journal article
Menezes, A. C.; Cripps, A.; Buswell, R. A. et al. (2014): Estimating the energy consumption and power demand of small power equipment in office buildings. Energy and Buildings, 75, pp. 199–209
Finding Guide values for the consumption of office equipment are often out of date and overlook how different devices and usage are. A bottom-up calculation, device by device with power and usage time, matched the measured monthly consumption well.
In the tool This is exactly how the tool calculates: device by device, with power per state and running time, instead of a flat value per workstation.
doi.org/10.1016/j.enbuild.2014.02.011 · Journal article
Abrahamse, W.; Steg, L.; Vlek, C.; Rothengatter, T. (2005): A review of intervention studies aimed at household energy conservation. Journal of Environmental Psychology, 25 (3), pp. 273–291
Finding Review of 38 studies: information alone increases knowledge but seldom changes behaviour. Feedback on your own consumption works, especially when it comes often.
In the tool That is why the calculator shows euros and kWh per device rather than just a total, and advises re-measuring with an energy meter plug.
doi.org/10.1016/j.jenvp.2005.08.002 · Review
Hawkes, A. D. (2010): Estimating marginal CO2 emissions rates for national electricity systems. Energy Policy, 38 (10), pp. 5977–5987
Finding For Great Britain, the emission factor of the additionally generated kilowatt-hour in 2002 to 2009 was 0.69 kg CO₂, above the usual average values.
In the tool In the limitations, the calculator uses the average of the electricity mix; what a saved kilowatt-hour actually avoids can differ from that.
doi.org/10.1016/j.enpol.2010.05.053 · Journal article
Standards, authorities and manufacturer data
- BDEW electricity price analysis October 2026, households and industry · BDEW
- Development of the specific greenhouse gas emissions of the German electricity mix 1990–2025 (Climate Change 16/2026) · Umweltbundesamt
- ENERGY STAR Certified Computers V9.0 (data set) · US EPA
- ENERGY STAR Certified Displays (data set) · US EPA
- ENERGY STAR Certified Enterprise Servers (data set) · US EPA
- ENERGY STAR Certified Imaging Equipment (data set, TEC) · US EPA
- Standby, networked standby and off mode (Regulation (EU) 2023/826) · European Commission
- Data sheets FRITZ!Box 7530 AX and 7590 AX (power consumption) · AVM
- TL-SG108 and TL-SG1024D, specifications · TP-Link
- EAP610, specifications (power consumption over PoE) · Omada (TP-Link)
- DiskStation DS224+, specifications (power consumption) · Synology
09 / MORE TOOLS
Still have a question?
- AT-W2 · Home & business
Windows 10 check
Does this PC still get security updates, and what needs doing by October 2027? - AT-W3 · Home & business
Wi-Fi planner
How many access points or mesh units does your home, office or warehouse need? - AT-W4 · Businesses
IT emergency check
How quickly could your business get back to work after an outage? - AT-W5 · Businesses
E-mail check
Are your e-mails landing in spam? Your domain’s SPF, DKIM and DMARC in plain language. - AT-W6 · Businesses
UPS calculator
Which UPS keeps your server, router and till running long enough during a power cut? - AT-W7 · Home
Digital legacy planning sheet
Which accounts, devices and contracts should your family know about?
Do you have your device list? Send us the copied result. We re-measure where it is worthwhile and suggest efficient devices or one server for everything, in Rodewisch and across the Vogtland.
+49 3744 4399760[email protected]Mon–Fri 8:00–17:00 · Straße der Jugend 5, 08228 Rodewisch