Electricity cost calculator: what do a PC, server and NAS cost per year?

How much electricity a device needs comes from its power times its running time, and running time decides: a small server that runs around the clock uses more in a year than three office PCs with monitors put together. The calculator takes values for load, idle and standby from Energy Star and manufacturer data sheets and shows the biggest items. In the example office it adds up to 1,227 kWh a year, around €458. You also see when a more efficient device pays for itself.

  • free
  • no sign-up
  • runs in your browser

Enter devices, read off consumption and cost

Calculator · Device list, costs and CO₂

Guide values. The templates are averages from Energy Star, data sheets and experience; your device may differ considerably. A measured value is always better.

Step 1Which devices do you run?

A small office is preset. Standby means sleep mode or switched off but still plugged in. All values can be overwritten.

    How do I find out the real consumption?
    • Energy meter plug. The most accurate method is an energy meter plug: one week between the wall and the device, then read off the kWh and multiply by 52.
    • Data sheet. Look for “power consumption in operation”, “idle” and “standby”. For a printer, the weekly TEC value in kWh.
    • Not the rating plate. It shows the most the power supply can deliver. A server with a 500 W power supply often draws only a quarter of that in daily use.
    • Servers and UPS. The remote management of many servers and the display of a UPS show the current power in watts.
    Step 2Electricity price and CO₂

    Preset: 37.3 cents, the 2026 average for households according to BDEW, including VAT. Businesses that deduct input VAT calculate net, which is around 31.3 cents. The unit price (Arbeitspreis) on your bill is more accurate.

    Preset: 344 g, the 2025 electricity mix according to the Umweltbundesamt. Including upstream emissions (fuels, power plant construction) it is 406 g. The figure for your supplier is given in the electricity labelling on the bill.

    Electricity per year

    —

    Enter at least one device with a wattage.

    Step 3Is a more efficient device worth it?

    Choose a template or enter your own values. The usage applies to both devices.

    Existing device

    New device

    Many manufacturers give the CO₂ figure for manufacturing in the “Product Carbon Footprint” for the model.

    Savings from the swap

    —

    Guide values, as of 14 November 2026. We procure efficient devices through hardware ordering; the easiest way to send us your device list is to copy it into the contact form.

    Runs in your browser. Nothing is sent or stored.

    What IT devices use per year

    A device has three states. Under load it is working, when idle it is switched on and waiting, in standby it sleeps or is off but still on the mains. How much it needs in a year depends less on the peak than on how long it spends in each state. A server mostly works at only 10 to 50 percent utilisation, yet even with almost no work it still draws about half of its full power Barroso and Hölzle 2007. That is why the idle figure is the most important number for devices that run all the time.

    The values in the calculator are not rating-plate figures. A rating plate shows what the power supply can deliver at most, and even when planning data centres such figures are of limited use, because consumption varies strongly with the work done Fan et al. 2007. If you enter more than 1,000 W per device, you therefore get a query. For PCs, monitors and servers, idle and standby come from the Energy Star data sets: each is the median of all certified models, as of 13 November 2026. Routers, switches, access points and NAS are listed with manufacturers’ data sheet values. Anything marked “estimate” is based on our experience.

    The calculation goes device by device, with power per state and running time. This bottom-up method matches the measured consumption of offices much better than flat values per workstation Menezes et al. 2014. When a device is on, the calculator uses idle plus utilisation times the gap to load. That is the simplest of the common consumption models, and how accurate such models are is often an open question in research too Dayarathna et al. 2016.

    Templates in the calculator, yearly consumption at 37.3 ct per kWh
    DeviceLoadIdleStandbyUsagekWhEuroSource
    Office PC, newer model60 W10,5 W1.6 W8 h a day, 5 days5320 €Idle and sleep mode: Energy Star median of certified models, as of 13.11.2026 · Estimate: load, usage
    Office PC, older (before about 2016)90 W40 W3 W8 h a day, 5 days12446 €Figure from experience · Estimate: load, idle, standby, usage
    Mini PC or thin client25 W4,7 W0,8 W8 h a day, 5 days248,81 €Idle and sleep mode: Energy Star median of certified models, as of 13.11.2026 (thin clients) · Estimate: load, usage
    Laptop on mains power30 W4,9 W0,6 W8 h a day, 5 days259,21 €Idle and sleep mode: Energy Star median of certified models, as of 13.11.2026 · Estimate: load, usage
    All-in-one PC with screen60 W15,9 W2 W8 h a day, 5 days6524 €Idle and sleep mode: Energy Star median of certified models, as of 13.11.2026 · Estimate: load, usage
    Workstation (CAD, graphics)250 W70,1 W4,3 W8 h a day, 5 days25093 €Idle and sleep mode: Energy Star median of certified models, as of 13.11.2026 · Estimate: load, usage
    Monitor, 24 inch12,9 W12,9 W0,2 W8 h a day, 5 days2811 €Operation and sleep mode: Energy Star median of certified models, as of 13.11.2026 (23 to 25 inch) · Estimate: usage
    Monitor, 27 inch16,9 W16,9 W0,2 W8 h a day, 5 days3714 €Operation and sleep mode: Energy Star median of certified models, as of 13.11.2026 (26.5 to 28.9 inch) · Estimate: usage
    Monitor, 32 inch27,7 W27,7 W0,4 W8 h a day, 5 days6023 €Operation and sleep mode: Energy Star median of certified models, as of 13.11.2026 (29 to 32.9 inch) · Estimate: usage
    Laser printer or multifunction device3,3 W3,3 W3,3 Waround the clock2911 €Average from the Energy Star weekly TEC value (median 0.55 kWh, black-and-white laser)
    Router (e.g. FRITZ!Box 7530 AX)6 W6 W6 Waround the clock5320 €AVM data sheet: average power consumption 6 W
    Router with telephony (e.g. FRITZ!Box 7590 AX)15 W15 W15 Waround the clock13149 €AVM data sheet: 14 to 16 W on average
    Fibre modem (ONT)6 W6 W6 Waround the clock5320 €Figure from experience · Estimate: load, idle, standby
    Switch, 8 ports3,3 W3,3 W3,3 Waround the clock2911 €TP-Link TL-SG108: 3.31 W at most according to the data sheet
    Switch, 24 ports13,6 W13,6 W13,6 Waround the clock11944 €TP-Link TL-SG1024D: 13.62 W at most according to the data sheet
    Wi-Fi access point Wi-Fi 6 (PoE)13,7 W13,7 W13,7 Waround the clock12045 €Omada EAP610: 13.7 W at most over PoE according to the data sheet
    Firewall (desktop unit)20 W20 W20 Waround the clock17565 €Figure from experience · Estimate: load, idle, standby
    Phone system25 W25 W25 Waround the clock21982 €Figure from experience · Estimate: load, idle, standby
    IP phone (PoE)4 W4 W4 Waround the clock3513 €Figure from experience · Estimate: load, idle, standby
    IP camera (PoE)7 W7 W7 Waround the clock6123 €Figure from experience · Estimate: load, idle, standby
    NAS with 2 drives (e.g. Synology DS224+)14,7 W14,7 W4,4 Waround the clock12948 €Synology: 14.69 W during access, 4.41 W with drives in sleep mode
    NAS with 4 drives (e.g. Synology DS923+)35,5 W35,5 W11,5 Waround the clock311116 €Synology: 35.51 W during access, 11.52 W with drives in sleep mode
    Tower server, 1 processor120 W51,9 W5 Waround the clock574214 €Idle: Energy Star median of certified models, as of 13.11.2026 (SERT, 1 socket, tower) · Estimate: load, standby, usage
    Rack server, 1 processor200 W128,3 W8 Waround the clock1.250466 €Idle: Energy Star median of certified models, as of 13.11.2026 (SERT, 1 socket, rack) · Estimate: load, standby, usage
    Rack server, 2 processors350 W185,9 W10 Waround the clock1.916715 €Idle: Energy Star median of certified models, as of 13.11.2026 (SERT, 2 sockets, rack) · Estimate: load, standby, usage

    Workstation devices at 20 % utilisation, servers likewise. Energy Star data sets retrieved on 14 November 2026; data sheets from AVM, TP-Link, Omada and Synology; dates are listed in the sources.

    EXAMPLE OFFICE · kWh PER YEARTower server574 kWh3 × office PC160 kWhRouter with telephony131 kWhNAS, 2 drives129 kWhSwitch 24 ports119 kWh3 × 24 in monitor85 kWhLaser printer29 kWhLOADBASE LOADSTANDBY

    Fig. 1 · The calculator’s preset: 82 % of the electricity is base load of devices that are switched on, meaning idle and power supplies in continuous operation; only 15 % comes from load.

    Network and standby: small, but never off

    Routers, switches and access points draw little, but for 8,760 hours a year, and their consumption hardly depends on the amount of data. In the USA, network devices used around 1 percent of the electricity in buildings in 2008; the biggest items were switches in office buildings and the devices in homes Lanzisera et al. 2012. In measurements in ten homes, the standby of all devices alone accounted for 5 to 26 percent of yearly consumption Ross and Meier 2002.

    Since then the EU has tightened the rules. Since 2025, new household and office devices may draw no more than 0.5 W in standby and off mode, or 0.8 W with a status or information display; from 2027 the off mode drops to 0.3 W. For networked standby the limit since 2025 is 2 W; only devices with high network availability may draw 8 W, and from 2027 7 W (Regulation (EU) 2023/826, according to the European Commission). A monitor in standby therefore hardly matters any more; an older power supply sitting warm on the desk matters more. For printers the calculator uses the weekly TEC value from the data sheet, which includes printing, standby and sleep mode; how laser and inkjet compare otherwise is covered in the guide Buying a printer: inkjet or laser.

    Electricity price and CO₂ factor: where the values come from

    The preset is the average price for households from the BDEW electricity price analysis of October 2026. It applies to 3,500 kWh a year, includes a share of the standing charge and VAT, and is based on tariffs that can be newly signed. The value is 37.3 ct per kWh. Small businesses without a special contract pay a similar amount, but deduct the VAT as input VAT and calculate net at around 31.3 ct. According to BDEW, small and medium-sized industrial businesses with supply contracts from 160,000 kWh were at 17.9 cents.

    Strictly speaking, only the unit price (Arbeitspreis) counts for a saving, that is the price per additional kilowatt-hour. The standing charge stays even when a device is off. It is therefore best to enter the unit price from your bill. Older contracts are often above the average of new tariffs.

    The CO₂ figure comes from the Umweltbundesamt. For 2025 it estimates the direct emission factor of the German electricity mix at 344 g CO₂ per kWh, after 353 g in 2024. If you add methane and nitrous oxide as well as the upstream chain, meaning fuel extraction and power plant construction, it is 406 g CO₂ equivalents.

    Both values are averages across all power plants. What a saved kilowatt-hour actually avoids depends on which power plant runs less because of it; in Great Britain this marginal value was clearly above the average Hawkes 2010. The CO₂ saving in the calculator is therefore on the cautious side.

    Values set and alternatives
    ParameterValueSource, date
    CO₂, electricity mix 2025 (direct, preset)344 g/kWhUBA, March 2026, estimated
    CO₂, electricity mix 2024353 g/kWhUBA, provisional
    Greenhouse gases with upstream chain 2025406 g/kWhUBA, CO₂ equivalents
    Electricity price for households 2026 (preset)37,3 ctBDEW, October 2026, incl. VAT
    The same price net31,3 ctwithout 19 % VAT, for businesses
    Industry, 160,000 kWh to 20 million kWh17,9 ctBDEW, October 2026

    When a more efficient device pays off

    Computing power per kilowatt-hour has roughly doubled every year and a half over decades Koomey et al. 2011, and even in data centres efficiency gains have largely absorbed the growing demand Masanet et al. 2020. A new device therefore almost always needs less electricity for the same work. Whether the swap pays off is still a separate question: the yearly saving times the service life gives the maximum amount the swap may cost.

    Examples using the templates, usage as for the old device
    SwapUsagekWh lessCO₂ lessEuro per yearmay cost (5 yrs)
    Office PC, older (before about 2016) → Office PC, newer model8 h a day, 5 days7124 kg27 €133 €
    Office PC, older (before about 2016) → Mini PC or thin client8 h a day, 5 days10135 kg38 €188 €
    Rack server, 2 processors → Rack server, 1 processoraround the clock666229 kg249 €1.243 €
    Router with telephony (e.g. FRITZ!Box 7590 AX) → Router (e.g. FRITZ!Box 7530 AX)around the clock7927 kg29 €147 €

    The older office PC is an estimate. If you want to work out a swap properly, measure the old device for a week.

    The table shows the pattern. For workstations with office hours the saving stays small, because the PC sleeps for most of the year. For devices that run around the clock it becomes noticeable, and it brings the most when one new server replaces two or three old ones. How we consolidate and virtualise servers is described under Servers and virtualisation.

    Manufacturing counts too

    A new device already has its CO₂ footprint before it is switched on. In a life-cycle assessment of eleven IT devices, these emissions were closely tied to mass; newer devices caused 50 to 60 percent less than older ones with a similar function Teehan and Kandlikar 2013. Anyone who keeps using a working laptop for longer or buys one second-hand clearly reduces the environmental impact, because so much is bound up in the components André et al. 2019. In the calculator you can enter the manufacturer’s figure; many manufacturers publish it as the “Product Carbon Footprint”. You then see after how many years the lower consumption makes up for the manufacturing.

    Our rule of thumb: a workstation PC is replaced when it is due, for example because support ends or it becomes too slow, and then deliberately with an efficient model. Whether repairing an older device is still worthwhile is worked out by Repair or buy new; how it is written off for tax is covered by the IT depreciation calculator. If the old device is passed on, everything should be securely erased first, as described in the guide Disposing of an old PC.

    How to reduce the electricity use of your IT

    1. Measure first. An energy meter plug shows in a week what a device really draws. Feedback on your own consumption demonstrably changes behaviour, whereas information alone hardly does Abrahamse et al. 2005.
    2. Switch on the power plan. In night-time walk-throughs of 16 offices, schools and practices, only one in seventeen desktop PCs went into power-saving mode by itself, and simply switching off would have brought consumption below 40 percent Webber et al. 2006. Sleep mode after 15 to 30 minutes, screen off after 10 minutes; in businesses this is set centrally, see Office PCs & laptops.
    3. Wake instead of leaving on. Updates and remote support are no reason to leave PCs on at night. Wake-on-LAN wakes them when needed; the network chip keeps the connection while the computer sleeps Nordman and Christensen 2010.
    4. Schedules for devices that run all the time. The NAS can stop its drives at night or switch off completely, access points can be switched off with a PoE schedule, and the FRITZ!Box has a Wi-Fi night switch. This does not affect the battery of a UPS, and the NAS and RAID calculator works out the storage size of the NAS.
    5. Consolidate servers. Every server draws a large part of its full load even without work Barroso and Hölzle 2007. If two or three small servers run side by side, one virtualised machine saves this base load several times over.
    6. Cut standby. A switchable power strip at the workstation disconnects the monitor, speakers and chargers completely from the mains after work.
    7. When buying, look at idle. For devices that run a lot, the idle figure on the data sheet matters more than the peak. Energy Star publishes it for certified PCs, monitors and servers.

    Where the calculator stops

    • Guide values instead of measurement. The templates are medians of certified models, data sheet values or marked estimates. Your device may be about half above or below these values.
    • Simple model. When a device is on, the tool calculates linearly between idle and load. It does not capture short peaks, inrush currents and power supply losses at very low load.
    • Average price. Calculated with a share of the standing charge; for savings, the unit price (Arbeitspreis) on your bill is what counts.
    • Average CO₂. Electricity mix as a yearly average; the manufacturing of new devices only if you enter it.

    If you want to know exactly, we measure the consumption of your devices, consolidate servers and replace power guzzlers where it pays off. We procure efficient devices through hardware ordering.

    Using this tool from an AI assistant

    Assistants such as Claude or ChatGPT that speak the Model Context Protocol (MCP) can call this page’s calculation directly instead of rebuilding it. The server is public, needs no sign-in and stores nothing. The answer always includes the link to this page, the date of the data and the limits of the result.

    Endpoint
    https://aureum-tech.com/mcp
    Tool
    werkzeug_stromkosten_rechner
    Transport
    Streamable HTTP, read-only
    Inputs
    NameRequiredMeaning
    geraeteyesDevice list. Each device with a template or its own wattage values, e.g. [{"vorlage":"pc","anzahl":3},{"vorlage":"tower"}].
    strompreis_ctnoUnit price in cents per kWh. If omitted, 37.3 (BDEW electricity price analysis October 2026, 2026 average for households (3,500 kWh, standing charge pro rata, incl. VAT)). Businesses that deduct input VAT calculate net.
    co2_g_kwhnoCO₂ in grams per kWh. If omitted, 344 (UBA, electricity mix 2025); with upstream chain 406.
    vergleichnoOptional: comparison of old and new with savings and payback.

    Questions where an assistant should call it

    • “What does a server that runs around the clock cost in electricity per year?”
    • “How much electricity do three office PCs with monitors, a NAS and a FRITZ!Box use per year?”
    • “Is it worth replacing an old office PC with a mini PC if that costs 500 euros?”
    • “How much CO₂ does my NAS cause per year, and what does drive sleep mode save?”

    How the connection works and what MCP can do in your own business is explained on the page about MCP integrations.

    Common questions about electricity use and electricity costs

    How much electricity does a PC use per year?

    A newer office PC used 8 hours a day on 5 days a week needs around 53 kWh a year; certified devices draw only 10.5 W on average when idle. An older PC with the same use comes to more like 124 kWh, and if you leave the newer one running around the clock it ends up at 179 kWh. At 37.3 ct per kWh that is €20, €46 and €67 a year.

    What does a server cost in electricity per year?

    A server runs around the clock, so 8,760 hours a year, and even with no work to do it draws a large part of its full load. A tower server with one processor therefore needs around 574 kWh a year, a rack server with two processors around 1,916 kWh. That is €214 and €715 a year. Consolidating several old servers onto one new one usually saves more than any other step.

    How much electricity does a FRITZ!Box use?

    According to the AVM data sheet, a FRITZ!Box 7530 AX draws 6 W on average, and a FRITZ!Box 7590 AX with telephony and DECT 14 to 16 W. Around the clock that is 53 kWh and 131 kWh a year, or €20 and €49. The Wi-Fi night switch saves only part of that, because phone and internet keep running.

    How much electricity does a NAS use?

    Synology gives 14.69 W during access and 4.41 W with the drives in sleep mode for a two-drive NAS (DS224+). If the drives run all the time, that is 129 kWh a year; with 8 hours of sleep mode every night it is 99 kWh. That comes to €48 and €37 a year; you then schedule the backup for the hours before sleep mode.

    Is it worth replacing an old PC because of its electricity use?

    Rarely on electricity alone. A newer office PC saves around 71 kWh a year compared with an older one at office hours, and making the new device causes CO₂ of its own. For the swap to pay for itself through electricity within 5 years, it could cost no more than €133. It looks different for devices that run around the clock, or if the PC is due for replacement anyway. Then it is worth checking the idle figure on the data sheet.

    Which electricity price and which CO₂ figure are set?

    The electricity price is the 2026 average for households from the BDEW electricity price analysis of October 2026, including VAT (MwSt.) and a share of the standing charge. The CO₂ figure is the emission factor of the German electricity mix for 2025 according to the Umweltbundesamt. The preset values are 37.3 ct per kWh and 344 g CO₂ per kWh; businesses that can deduct input VAT (Vorsteuer) calculate net, at around 31.3 ct. You can change both.

    What is the difference between idle and standby?

    Idle means the device is switched on and ready but not working, such as a PC showing the desktop. Standby means sleep mode, standby or switched off with the plug still in the socket. Since 2025, new household and office devices may draw no more than 0.5 W in standby and off mode, or 0.8 W with a display (Regulation (EU) 2023/826). PCs and servers have rules of their own.

    Where does the electricity cost calculator stop?

    It works with guide values per device and a simple model between idle and load. Only a measurement shows what your devices really draw. We measure the consumption of your devices on site in Rodewisch and across the Vogtland, consolidate servers and replace power-hungry devices where it pays off.

    What the tool is based on

    The guide values and notes above are based on these 14 scientific papers. Each one has been checked via its DOI or the publisher’s page (most recently on 14 November 2026): it exists, it has not been retracted, and its findings still hold for this question today.

    1. Barroso, L. A.; Hölzle, U. (2007): The Case for Energy-Proportional Computing. Computer (IEEE), 40 (12), pp. 33–37

      Finding Servers are seldom idle and seldom at full load, mostly between 10 and 50 % utilisation. Even an efficient server with almost no work still draws about half of its full power.

      In the tool The server templates have their own idle value, utilisation is preset to 20 %, and with several servers the calculator advises consolidating them.

    2. Fan, X.; Weber, W.-D.; Barroso, L. A. (2007): Power provisioning for a warehouse-sized computer. Proceedings of the 34th Annual International Symposium on Computer Architecture (ISCA), pp. 13–23

      Finding Anyone planning electricity for many servers faces two uncertainties: the power ratings of the devices are of limited use, and consumption varies strongly with the actual computing work.

      In the tool The templates are operating values, not rating-plate values, and above 1000 W per device the calculator asks whether the rating plate was copied.

    3. Dayarathna, M.; Wen, Y.; Fan, R. (2016): Data Center Energy Consumption Modeling: A Survey. IEEE Communications Surveys & Tutorials, 18 (1), pp. 732–794

      Finding Review of more than 200 consumption models for data centres and their components. Many models rely on a few variables such as processor utilisation, and how accurate they are is often an open question.

      In the tool The calculator uses the simplest of these models, idle plus utilisation times the gap to load, and describes it as an approximation in the limitations.

    4. Lanzisera, S.; Nordman, B.; Brown, R. E. (2012): Data network equipment energy use and savings potential in buildings. Energy Efficiency, 5 (2), pp. 149–162

      Finding In 2008, network devices in the USA used around 18 TWh, about 1 % of the electricity in buildings. The biggest items were switches in office buildings (40 %) and devices in homes (30 %); efficient technology could save 20 to 50 %.

      In the tool Router, switch and access point are in the list with their own data sheet values for continuous operation, and for access points the calculator suggests a schedule.

    5. Ross, J. P.; Meier, A. (2002): Measurements of whole-house standby power consumption in California homes. Energy, 27 (9), pp. 861–868

      Finding In ten homes, the devices in standby together drew 14 to 169 W, 67 W on average, which was 5 to 26 % of yearly consumption. Devices with the same task differed greatly in standby.

      In the tool Standby is a column of its own in the calculator, and from a 10 % share of consumption it suggests a switchable power strip.

    6. Webber, C. A.; Roberson, J. A.; McWhinney, M. C. et al. (2006): After-hours power status of office equipment in the USA. Energy, 31 (14), pp. 2823–2838

      Finding Night-time walk-throughs of 16 offices, schools and practices: most types of device were switched off less than half the time, and only 6 % of desktop PCs went into power-saving mode by themselves. If the devices were switched off at night, their consumption would fall to under 40 % according to the authors’ extrapolation (factor 2.6).

      In the tool If a workstation device runs for more than 10 hours a day, the calculator works out what the power plan or switching off would bring.

    7. Nordman, B.; Christensen, K. (2010): Proxying: The Next Step in Reducing IT Energy Use. Computer (IEEE), 43 (1), pp. 91–93

      Finding A low-power proxy, for example in the network chip, keeps the connection to the network while the PC sleeps. That way a computer can rest without disappearing from the network.

      In the tool Gives the reason for the advice to wake PCs for remote support and updates with Wake-on-LAN instead of leaving them running at night.

    8. Koomey, J.; Berard, S.; Sanchez, M.; Wong, H. (2011): Implications of Historical Trends in the Electrical Efficiency of Computing. IEEE Annals of the History of Computing, 33 (3), pp. 46–54

      Finding Computing power per kilowatt-hour has roughly doubled every year and a half over more than six decades.

      In the tool This is why there is a comparison of old and new, and older PCs have a template of their own with higher values.

    9. Masanet, E.; Shehabi, A.; Lei, N. et al. (2020): Recalibrating global data center energy-use estimates. Science, 367 (6481), pp. 984–986

      Finding The electricity demand of data centres has grown more slowly than often predicted, because strong efficiency gains have largely absorbed the extra demand.

      In the tool Supports the comparison for servers: a new server usually does the same work with less electricity, especially when it replaces several old ones.

    10. Teehan, P.; Kandlikar, M. (2013): Comparing Embodied Greenhouse Gas Emissions of Modern Computing and Electronics Products. Environmental Science & Technology, 47 (9), pp. 3997–4003

      Finding Life-cycle assessment of the manufacture of eleven IT devices, including desktop PCs, laptops, a thin client, a monitor, a server and a switch. Emissions are closely tied to mass; newer devices caused 50 to 60 % less than older ones with a similar function.

      In the tool In the comparison you can enter the manufacturing of the new device; the calculator then states after how many years the lower consumption has made up for it.

    11. André, H.; Ljunggren Söderman, M.; Nordelöf, A. (2019): Resource and environmental impacts of using second-hand laptop computers: A case study of commercial reuse. Waste Management, 88, pp. 268–279

      Finding Used laptops from commercial refurbishment instead of new ones: the longer use clearly reduced all environmental impacts examined, because so much is bound up in the components. The effort for testing and shipping hardly mattered.

      In the tool Gives the reason for the advice not to replace a working device on electricity grounds alone, and for the advice to pass devices on rather than throw them away.

    12. Menezes, A. C.; Cripps, A.; Buswell, R. A. et al. (2014): Estimating the energy consumption and power demand of small power equipment in office buildings. Energy and Buildings, 75, pp. 199–209

      Finding Guide values for the consumption of office equipment are often out of date and overlook how different devices and usage are. A bottom-up calculation, device by device with power and usage time, matched the measured monthly consumption well.

      In the tool This is exactly how the tool calculates: device by device, with power per state and running time, instead of a flat value per workstation.

    13. Abrahamse, W.; Steg, L.; Vlek, C.; Rothengatter, T. (2005): A review of intervention studies aimed at household energy conservation. Journal of Environmental Psychology, 25 (3), pp. 273–291

      Finding Review of 38 studies: information alone increases knowledge but seldom changes behaviour. Feedback on your own consumption works, especially when it comes often.

      In the tool That is why the calculator shows euros and kWh per device rather than just a total, and advises re-measuring with an energy meter plug.

    14. Hawkes, A. D. (2010): Estimating marginal CO2 emissions rates for national electricity systems. Energy Policy, 38 (10), pp. 5977–5987

      Finding For Great Britain, the emission factor of the additionally generated kilowatt-hour in 2002 to 2009 was 0.69 kg CO₂, above the usual average values.

      In the tool In the limitations, the calculator uses the average of the electricity mix; what a saved kilowatt-hour actually avoids can differ from that.

    Standards, authorities and manufacturer data

    Mon–Fri 8:00–17:00

    Do you have your device list? Send us the copied result. We re-measure where it is worthwhile and suggest efficient devices or one server for everything, in Rodewisch and across the Vogtland.

    +49 3744 4399760[email protected]

    Mon–Fri 8:00–17:00 · Straße der Jugend 5, 08228 Rodewisch

    Have your consumption checked
    +49 3744 4399760Mon–Fri 8:00–17:00
    CallCallback

    PARTS LIST · SHEET 1/1

    What this page is made of

    Values measured at build time. With JavaScript, your browser measures them again live.

    ITEMPARTTYPESIZE
    01index.htmlDocument≈ 29 kB
    02styles.cssStylesheet≈ 20 kB
    03scripts.jsScript≈ 13 kB
    04archivo-variable.woff2Font≈ 58 kB
    05ibm-plex-mono.woff2Font≈ 30 kB
    06favicon.svgImage< 1 kB

    Advertising or analytics cookies: none. Without your consent, the page loads nothing from third-party servers apart from Cloudflare, our delivery service. Fonts, scripts and images are hosted by us. That is how we build your IT, too.

    OUTSIDE OFFICE HOURS

    Feel free to call anyway

    Our regular office hours are Monday to Friday, 8:00–17:00.

    In the evening and at weekends the number is forwarded to us, and often someone will pick up. We cannot promise that, though.

    If nobody answers, leave a short message on the voicemail: your name, your number and what it is about. We will call back as soon as we can, on the next working day at the latest.

    The call costs nothing. If someone has to start work straight away outside office hours, the surcharge in the price list applies.

    Call now+49 3744 4399760

    Prefer to write? Use the contact form or e-mail [email protected]. We will read it on the next working day.

    DIAGNOSIS · AT-K2

    What do you need help with?

    ↵ SELECTESC CLOSECALL: +49 3744 4399760

    Custom settings

    Which services may load?

    Strictly necessary

    The choice you make here and your settings for colour scheme and motion. These are kept as small entries on your device and are never sent to a server. They are needed for the site to work and therefore cannot be switched off.